Strona 1 - OWNER'S MANUAL

STANDBY GENERATOROWNER'S MANUALThis manual should remain with the unit.A new standard of reliabilitySerial NumberQT2.4L45kWModel: 005262-0—CA

Strona 2 - Table of Contents

SPECIFICATIONSGENERATORType ... SynchronousRotor Insulation ...

Strona 3 - WARNING:

COLD WEATHER KITFor cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes:• Battery Warmer• 4” Junction Box

Strona 4 - EXPLOSION HAZARDS

GENERATOR AC LEAD CONNECTIONSSee “Voltage Codes”. This generator may be rated at any one of three voltages, either single-phase or three-phase. The el

Strona 5 - INTRODUCTION

INSTALLATIONRefer to the separate “Installation Guide QT Product Line” supplied with the unit.PREPARATION BEFORE START-UPThe instructions in this sect

Strona 6 - IDENTIFICATION RECORD

START-UP CHECKLIST Before working on the generator, ensure the fol-lowing:• The AUTO/OFF/MANUAL switch is in the OFF position.• The 120VAC supply to

Strona 7 - COOLANT RECOMMENDATIONS

GENERATOR CONTROL AND OPERATIONRefer to the appropriate control panel operator’s manual for this unit.OPERATING UNIT WITH MANUAL TRANSFER SWITCHIf the

Strona 8 - ENGINE PROTECTIVE DEVICES

MAINTENANCE PERFORMED BY AUTHORIZED SERVICE FACILITIES  Before working on the generator, ensure the fol-lowing:• The AUTO/OFF/MANUAL switch is in th

Strona 9 - FUEL SYSTEM

Figure 10.1 - Oil Dipstick and Oil Fill CapOil Fill CapOilDipstickBATTERY FLUIDCheck battery electrolyte fluid based on the Maintenance Schedule. Flui

Strona 10 - SPECIFICATIONS

CHANGING ENGINE OILRefer to maintenance performed by authorized service facilities for engine oil and filter change frequencies.Drain the oil while th

Strona 11 - Figure 1 — Interconnections

MISCELLANEOUS MAINTENANCECLEANING THE GENERATORKeep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen-

Strona 12 - CONNECTIONS

Standby Generator SetsTable of ContentsSECTION PAGESAFETY RULES ... 1-1INTRODUCTION ...

Strona 13 - PREPARATION BEFORE START-UP

SERVICE SCHEDULE30 KW - 150 KW STANDBY GAS ENGINE DRIVEN GENERATOR SETSThe following is a recommended maintenance schedule for standby gas engine driv

Strona 14 - START-UP CHECKLIST

Maintenance Level 1 Level 2 Level 3 Level 4 Level5 Tasks Recom- Task Required Task Required Task Task Required Task mended Com

Strona 15 - Oper001 Rev. 0 08/05

Maintenance Level 1 Level 2 Level 3 Level 4 Level5 Tasks Recom- Task Required Task Required Task Task Required Task mended Com

Strona 16 - Maint010 Rev. 0 02/06

Maintenance Level 1 Level 2 Level 3 Level 4 Level5 Tasks Recom- Task Required Task Required Task Task Required Task mended Com

Strona 17 - OPERATOR CAN PERFORM

TROUBLESHOOTING GUIDEPROBLEM CAUSE CORRECTIONEngine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defective 2.

Strona 18 - Figure 10.2 – Oil Filter

Standby Generator SetsNotes

Strona 19 - MISCELLANEOUS MAINTENANCE

Standby Generator SetsNotes

Strona 20 - SERVICE SCHEDULE

Standby Generator SetsNotes

Strona 22

1 0F3137 1 PAN CB CONN BOX2 0F3188 1 STAND RH CONTROL3 0F3189 1 STAND LH CONTROL4 023484N 1 BUSHING SNAP SB-2.5-31 5 *** 0F6366B 1 / 2 XFMR DUAL 1

Strona 23

Study these SAFETY RULES carefully before install-ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the un

Strona 25

5) UL CIRCUIT BREAKER (QJ-2P)A 0F8137 1 COVER QJ 2P FRM CBB 065469 1 DECAL, DANGER HIGH VOLTAGEC 0E7994 - CB 0225A 240V 2P S QJ22D 0F8136 1 COVER QJ 2

Strona 27

1 0G0056 1 RTR-2390--35KD1 CPL0F9677 1 RTR-2390--45KD1 CPL2 0G0057 1 STR-2390--35AD1 CPL0F9664 1 STR 390 45K 2P 1PH DIRECT0G0058 1 STR-2390--35KD1 CPL

Strona 29

1.) C2 UNITS A 0F9832 1 SHIELD CONN BOX C20F9832GGS0R 1 SHIELD CONTROL STAND C2 B 0C2454 3 SCREW THF M6-1 X 16 N WA Z/JS2.) C3 UNITS A 0F9832B

Strona 31

COMPONENTS INCLUDED IN 0F9696E1 0F1823A 1 ENCL HSB CONTROL PANEL2 0F3078 1 COVER CONTROL PANEL3 0F2606 1 HINGE CONTINUOUS H-PANEL4 036261 6 RIVET POP

Strona 33

1 0F9517 1 WELDMENT FRAME 2.4L C22 052860 4 NUT FLANGED HEX M12-1.753 052251 5 DAMPENER VIBRATION 40 BLUE4 052257 5 SPACER .49 X .62 X 1.87 PWDR/ZNC5

Strona 34

• Before performing any maintenance on the gen-erator, disconnect its battery cables to prevent accidental start-up. Disconnect the cable from the bat

Strona 36

1 0F3408B 1 BATTERY TRAY C1 CPL2 0F3411 1 STRAP BATTERY RETAINMENT3 025507 REF WASHER SHAKEPROOF EXT 7/16 STL4 052647 REF SCREW SHC M10-1.5 X 25 G12.9

Strona 38

1 0G0158 1 ENGINE 2.4L HYUNDAI2 022131 3 WASHER FLAT 3/8-M10 ZINC3 0F9585 1 EXHAUST ADAPTER 2.4L MACH4 046525 3 NUT HEX M10-1.25 G8 YEL CHR5 052212 1

Strona 40

1 0F9529 1 WELDMENT RADIATOR SUPPORT 2.4L2 0F2608 1 RADIATOR 598 X 568 X 49 CPL RH3 0F5263 1 V-BELT 31/64" X 57-3/8"4046526 5WASHER LOCK M10

Strona 42

1 0E6586 1 GASKET BOSCH 32 & 402 0E0519A 1 ADAPTER CARBURETOR W/PVC CONN3 0C8127 1 ELEMENT AIR CLEANER4 052619 4 SCREW HHC M5-0.8 X 20 G8.85 02212

Strona 44

1 026915 2 NIPPLE CLOSE 3/4 X 1.3752 075580 1 FLANGE FUEL INLET3 0F6390B 1 REGULATOR ASSY 2.4L4 039253 2 SCREW HHC M8-1.25 X 20 G8.85 022145 2 WASHER

Strona 45

1-3INTRODUCTIONThank you for purchasing this model of the standby generator set product line.Every effort was expended to make sure that the informati

Strona 47

1 0G0045 (XX) 1 REAR WRAP C2 CPL2 0C2454 54 SCREW THF M6-1 X 16 N WA Z/JS3 0F5849 (XX) 2 DOOR C24 087233 2 RIVET POP .1875 X .450 SS5

Strona 49

1 0F9794 1 MUFFLER 7" X 9" X 18-1/2" 2" IN/OUT2 0G0113 1 EXHAUST ELBOW 2 1/4 OD 2 1/2OD3 0F9937 1 BRACKET MUFFLER4 0F2830 1 MUFFLE

Strona 52

Standby Generator SetsWarrantyPrinted in U.S.A.GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FORHOME STANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELOW

Strona 53

IDENTIFICATION RECORDDATA LABELEvery generator set has a DATA LABEL that contains important information pertinent to the generator. The data label, wh

Strona 54

EQUIPMENT DESCRIPTIONThis equipment is a revolving field, alternating cur-rent generator set. It is powered by a gaseous fueled engine operating at 18

Strona 55

ENGINE PROTECTIVE DEVICESThe standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine

Strona 56 - Warranty

FUEL SYSTEMFUEL REQUIREMENTSThe standby generator may be equipped with one of the following fuel systems:• Natural gas fuel system• Propane vapor (P