Generac 9600-3 Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 12
SPECIFICATIONS
GENERATOR SPECIFICATIONS
Rated Maximum Continuous
AC Output
...........................................
6600 watts (6.6 kW)
Rated Voltage
................................................
120 Volts AC*
Rated Maximum Continuous
AC Current at 120 volts
............................
55 AC amperesA
Phase..................................................................................1
Rated AC Frequency
...........................................
60 Hertz
Driven Speed of Rotor
.........................................
3600 RPM
Rotor Poles..........................................................................2
* All units are reconnectable to 120/240 volts (dual
voltage) output. Units are not listed per RVIA/ANSI
when reconnected for dual voltage output.
A Rated maximum continuous current at 240 volts is
27.5 amperes.
ENGINE SPECIFICATIONS
Type of Engine
...........
...................................
Twin Cylinder
Cooling Method
.....................................................
Air-cooled
Rated Horsepower.......................................16 at 3600 rpm
Displacement
...............................................................
480cc
Compression Ratio....................................................8.6 to 1
Cylinder Block
.....................................
Aluminum with cast
iron sieeve
Type of Governor
.....................................
Mechanical, fixed
speed
Engine Governed Speed
.......................................
2571 rpm
Air Cleaner
..........................................
Paper element with
foam pre-cleaner
Starter
.................................................
12 volts DC electric
Ignition System..............................
..............
Solid state with
flywheel magneto
Recommended Spark Plugs
Champion
....................................
RC12 YC
AC................................................R45S
Fram Autolite
...............................
65
Spark Plug Gap
...........................
0.030 inch (0.8mm)
FUEL REQUIREMENTS
The NP-66G generator is equipped with a gasoline fuel
system as standard equipment. Specific installations
may provide either a separate fuel tank for the gener
ator, or the generator may “share" the vehicle engine's
fuel tank.
NOTE: Some installations using a “shared” fuel tank
may have a generator fuel pickup tube that is shorter
than the vehicle engine’s pickup tube. Such an arrange
ment causes the generator engine to “run out of gas”
while adequate fuel in the vehicle remains in the tank.
To reduce lead and carbon deposits use high quality
UNLEADED gasoline with the generator. Leaded
REGULAR grade gasoline is an acceptable substitute.
NOTE: Using “Unleaded” gasoline contributes to
longer engine valve life by reducing lead and carbon
deposits.
CAUTION: Generac does not recommend using
any gasoline containing alcohol (such as “gaso-
hoi”). If you use any gasoline containing aicohol, it
must not contain more than 10 percent ethanoi and
it must be removed from the tank during storage.
Do NOT use any gasoiine containing methanol. If
you use gasoline with alcohoi, inspect more fre
quently for fuel leaks and other abnormalities.
ENGINE OIL REQUIREMENTS
Use a high quality detergent oil classified “For Service
SP and with an oil viscosity rating of SAE 10W-30 oil.
Do not pour in any additives to the recommended oil.
Engine crankcase capacity is 1.5 U.S. quarts. See
MAINTENANCE section for oil level check and filling
procedures.
-11
Przeglądanie stron 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 31 32

Komentarze do niniejszej Instrukcji

Brak uwag